Micro cavity based 2D photonic crystal biosensor for MDA-MB-231 breast cancer cell detection | IJET β Volume 11 Issue 5 | IJET-V11I5P30

International Journal of Engineering and Techniques (IJET)
Open Access β’ Peer Reviewed β’ High Citation & Impact Factor β’ ISSN: 2395-1303
Volume 11, Issue 5 | Published: October 2025
Author: Dr. Vijay Laxmi Kalyani
Abstract
This work proposes microcavity based 2D photonics crystal biosensors design for detection of MDA-MB-231 cell. The MD Anderson-Metastatic Breast-231 (MDA-MB-231) Cell is a human breast cancer cell line which is triple negative cell line. This is the most common disease in women worldwide. This study aims to detect MDA-MB-231 by using proposed microcavity based 2D photonics crystal biosensor design in this paper. Microcavities has been created by increasing the radius from 0.11 ΞΌm to 0.12 ΞΌm of silicon rods. Refractive index (R.I.) for normal cell (1.385) and MDA-MB-231 affected cancer cell (1.399) have been used. Changes in the R.I. of normal cell and infected cell has shown a distinct wavelength shift by using sensing mechanism. Plane wave expansion (PWE) method has been used for band gap calculation in the waveguide and Opti-FDTD (Finite difference time domain) software has been used for design and simulation. High Quality factor (Q-factor) 445.82, Sensitivity (S) 402.14 nm/RIU and Detection limit (DL) .000853 RIU has been achieved during simulation. In comparison with other works in literature, proposed work has displayed improved sensing capability. Therefore, the designed sensor is practicable and viable for future fabrication due to its fast, accurate and better transmission.
Keywords
MDA-MB-231 cell, Refractive Index (R.I.), Photonic Crystal, Finite Difference Time domain (FDTD), Photonic bandgap
Conclusion
In this study, microcavity based biosensor structure has been designed and analyzed for MDA-MB-231 breast cancer cell detection. All the simulation results were performed using opti-FDTD software and PWE method was utilized to identify the bandgap. By increasing the radius of silicon rods from .11 um to .12 um, the MDA-MB-231 cell exhibited maximum sensitivity 402.14 (nm/RIU), high quality factor (445.82) and detection limit (.000853) (RIU) were observed in microcavity based sensor structure. The proposed designed structure could be a promising candidate for early detection of breast cancer (MDA-MB-231 cell) due to its simple design.
References
1.Hero T, BΓΌhler H, Kouam PN, et al. (2019), βThe triple-negative breast cancer cell line MDA-MB 231 is specifically inhibited by the ionophore salinomycinβ, Anticancer Research 39: 2821β2827.
2.MDA-MB-231 cells Cytion. Available from: https://www.cytion.com/MDA-MB-231-Cells/300275.
3.Mousa S (2010), βBiosensors: the new wave in cancer diagnosisβ, Nanotechnology Science and Applications 1.
4.Vijayalakshmi D, Manimegalai CT (2021), βBreast Cancer Cell Recognition Using High Sensitivity Photonic Crystal Fiber Based Plasmonic Sensorβ, 8th International Conference on Signal Processing and Integrated Networks (SPIN), Noida, India, 2021, pp. 1064-1068, doi: 10.1109/SPIN52536.2021.9566064
5.Yang Y, Xiang Y, Qi X (2023), βDesign of photonic crystal biosensors for cancer cell detectionβ, Micromachines 14: 1478.
6.Baraty F, Hamedi S (2023), βLabel-Free cancer cell biosensor based on photonic crystal ring resonatorβ,Results in Physics 46: 106317.
7.Kalyani VL, Sharma DVK (2024), βDesign of nanocavity based 2D photonics crystal biosensors for breast cancer detectionβ, 2nd International Conference on Recent Innovations in Engineering, Technology, Management and Research (2nd ICRIETMR-2024), Bal Krishna Institute of Technology, Kota, ISBN Number: 978-81-930823-4-8.
8.Hossan A, Chowdhury MAS, Islam ST, et al. (2025) , βDesign and optimization of an optical ring resonator based biosensor for cancer detectionβ, Deleted Journal 2.
Jamil MdF, Uddin MdB, Tayef MdJR (2025), βGold and titanium dioxide enhanced PCF SPR biosensor for early breast cancer detection in near infrared spectrumβ, Sensing and Bio-Sensing Research 49: 100821.
Β© 2025 International Journal of Engineering and Techniques (IJET).

Digital Object Identifier (DOI)
IJET assigns a unique DOI to every accepted article via Zenodo for persistent linking and citation. Your articleβs DOI: https://doi.org/{{doi}}

Citations & Discovery
Citations are tracked via Google Scholar and DOI lookups. Use the links below to find where this article is cited.
- Google Scholar: Search Citations
- DOI Resolver: Open DOI